Notes

Efficiency: 6%

Used at: CERN

Lasers used: Dye, Ti:sapphire

Used: online

Reference: B. Marsh, V. Fedosseev, "RILIS Database" (2009)

Notes: There is a slight isotope shift in the AI. (e.g.: 13361.289 for 64Ni )

It might be worth testing the scheme with the 1st step starting from the gs. The population at 2000K is 40% in the gs and 26% in the thermal one. Transition strength is lower (1.7e6s-1) but with dye laser that could still be saturated.

Scheme

Ionization Potential: 61619.770 cm⁻¹ (NIST ASD, 2024)
Lasers used: Ti:Sa and Dye

Scheme table

Step λ (nm) From (cm⁻¹) Term To (cm⁻¹) Term Strength (s⁻¹)
1 305.170 204.787 3d9 4s 3D3 32973.376 3d8 4s 4p 3F4 6.0 × 107
2 611.276 32973.376 3d8 4s 4p 3F4 49332.593 3d9 4d 2.7 × 106
3 748.420 49332.593 3d9 4d 62694.074 AI

Scheme drawing

ni scheme, light mode ni scheme, dark mode

Download scheme drawing

Light color Dark color
PDF , PNG , SVG PDF , PNG , SVG

References

Submitted by

Katerina Chrysalidis