Skip to content

Zn scheme 1

Notes

Efficiency: ≤ 4.9 %

Used at: CERN

Lasers used: Dye, Ti:sapphire

Used: online

Notes: On 56-58Zn a problem with stable Fe (masses 56-58) contamination was observed, generated by the transition in Fe from 0 cm-1 -> 46 744.993 cm-1 with subsequent ionisation from the 532 nm

Scheme

Ionization Potential: 75769.310 cm⁻¹ (NIST ASD, 2024)
Lasers used: Ti:Sa and Dye

Scheme table

Step λ (nm) From (cm⁻¹) Term To (cm⁻¹) Term Strength (s⁻¹)
1 213.925 0.000 4s2 1S0 46745.413 4s 4p 1Po1 7.0 × 108
2 636.410 46745.413 4s 4p 1Po1 62458.560 4s 4d 1D2 4.7 × 107
3 532.000 62458.560 4s 4d 1D2 81255.552

Scheme drawing

zn scheme, light mode zn scheme, dark mode

Download scheme drawing

Light color Dark color
PDF , PNG , SVG PDF , PNG , SVG

References

Submitted by

Katerina Chrysalidis