Skip to content

Zr scheme 3

Notes

Developed at LLNL, USA with SHG TiSas

Scheme

Ionization Potential: 53507.832 cm⁻¹ (NIST ASD, 2024)
Lasers used: Ti:Sa

Scheme table

Step λ (nm) From (cm⁻¹) Term To (cm⁻¹) Term
1 378.160 0.000 4d25s2 (3F2) 26443.833 4d25s(a2D)5p (4F3)
2 369.727 26443.833 4d25s(a2D)5p (4F3) 53490.817 Rydberg

Scheme drawing

zr scheme, light mode zr scheme, dark mode

Download scheme drawing

Light color Dark color
PDF , PNG , SVG PDF , PNG , SVG

Saturation curves

FES

  • 90Zr normalized to 1.
  • Measured on LION at LLNL. TiSa system.
  • FES Beam focus 1.2 x 1.4 mm, 1000 Hz, 6.9 ns Pulsewidth.
  • SES set to 369.730 nm

FES , light mode FES , dark mode

Download saturation curve

Data table Light color Dark color
CSV PDF, PNG, SVG PDF, PNG, SVG

SES

  • SES beam focused to 1.1 x 1.1 mm, 1000 Hz, 5 ns pulsewidth.
  • Signal 90Zr normalized to 1.

SES, light mode SES, dark mode

Download saturation curve

Data table Light color Dark color
CSV PDF, PNG, SVG PDF, PNG, SVG

References

Submitted by

Manuel Raiwa